est 3 lcd display in stock

The Main Display interface is the primary user interface in the EST3 Life Safety System. The main display interface focuses on the emergency user by putting information important to the user up front. Hands free, the first highest priority event is shown. The display always gives the last highest priority event. Arriving at the panel and without opening the door the first and last alarm is given. Simple to understand lights and switches help the emergency user execute system commands with confidence.

est 3 lcd display in stock

The 3-LCD module mounts to the local rail over the nodes Central Processing Unit Module (3-CPU). The 3-LCD module is optional in any network node.The 3-LCD module mounts to the local rail over the nodes Central Processing Unit Module (3-CPU). The 3-LCD module is optional in any network node.Ensuring information clarity the 3-LCD uses a backlit high contrast supertwist graphical display. Eight lines of 21 characters provide the room needed to convey emergency information in a useful format.The 3-LCD always displays the last highest priority event even when the user is viewing other message queues. Further message flexibility is provided with EST3’s message routing ability. Messages from a node can display at every node on the network or messages can route to specific nodes only. Routing can be initiated at a specific time/shift change. There is no need to have messages display in areas that are not affected by an event.The 3-LCD can display messages in English, Spanish, French, and Russian. The bilingual display lets the operator select between either of two languages. Consult your representative for available language combinations.The EST3 system configures

est 3 lcd display in stock

WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.govEDWARDS 3-LCD

est 3 lcd display in stock

Established in 2003, JKFire commands an unflinching corporate trust in the field of fire, safety and security systems. JK works under the fundamental principle of providing effective systems that preempts any eventuality and defuses potential dangers.

est 3 lcd display in stock

The 3-LCDXL1 module mounts to the 3-CPU and extends over the first four local rail module slots. The 3-LCDXL1 module is optional in any network node. EST3 networks can support any combination of 3-LCDXL1 and 3-LCD display modules. Ensuring information clarity the 3-LCDXL1 uses a backlit high contrast supertwist display. 24 lines of 40 characters provide the room needed to convey emergency information in a useful format. The 3-LCDXL1 always displays the last highest priority event even when the user is viewing other message queues. Further message flexibility is provided with EST3’s message routing ability. Messages from a node can display at every node on the network or messages can route to specific nodes only. Routing can be initiated at a specific time/shift change. There is no need to have messages display in areas that are not affected by an event. The 3-LCDXL1 can display system messages in either English, French or Spanish. The EST3 system configures for Local or Proprietary operation in compliance with U.S. or Canadian marketplace requirements. The mode of operation is selected through the System Definition Utility (SDU) which may adjust the following operations slightly to fit the system operation selected.

The 3-LCD series of display modules is the primary user interface for the EST3 Life Safety System. Designed specifically to meet the latest Control Panel Standard the 3-LCDXL1 provides 8 simultaneous events to be displayed. Emergency operator information shows the first 7 highest priority events in addition to the most recent event. Simple to understand LEDs and switches help the emergency user to display information and execute system commands with confidence.

Located below the general status LEDs are four, LED / Switch common controls. The versatility of EST3 allows system designers to define the features as affecting a domain (defined group of nodes) or as global (affects all nodes) across the network. This feature is very useful when configuring systems with multiple buildings on one network. As an example, operating the reset in one building may have adverse effect in other buildings. With EST3, having operational differences between buildings on the same network is not a problem.

Pressing Reset starts the system’s reset operation. The yellow LED has three flash rates during reset. The LED flashes fast during the smoke power down phase of reset, flashes slow during the restart phase, and turns on steady for the restoral phase. The Reset LED turns off when the system is normal. Pressing Alarm Silence turns off all Notification Appliance Circuits defined as audible. The yellow LED turns on when silence is active via the Alarm Silence switch or via alarm silence software timers. Pressing Panel Silence turns off the system’s internal audible signal. The yellow LED turns on when panel silence is active.

The “Selected Alarm” window, lines 2, 3, 4 automatically display the first active event of the highest priority if the user has not taken control of the system. Once the emergency user takes control, this window displays user message selections. The system events window of the display shows system event information.

est 3 lcd display in stock

Ensuring information clarity the 3-LCDXL uses a backlit high contrast super-twist display. 24 lines of 40 characters provide the room needed to convey emergency information in a useful format.

The 3-LCDXL always displays the last highest priority event even when the user is viewing other message queues. Further message flexibility is provided with EST3’s message routing ability. Messages from a node can display at every node on the network or messages can route to specific nodes only. Routing can be initiated at a specific time/shift change. There is no need to have messages display in areas that are not affected by an event.

The EST3 system configures for Local or Proprietary operation in compliance with U.S. or Canadian marketplace requirements. The mode of operation is selected through the System Definition Utility (SDU) which may adjust the following operations slightly to fit the system operation selected.