FREE SHIPPING: qualified PC parts products will have free shipping via our choice of ground delivery methods to most addresses in the 48 continental United States. Oversized orders that require delivery by truck do not qualify. The transit time will vary by delivery address and our chosen ship method.
Perfect for meeting rooms and retail applications, the Christie® UHD751-P is a budget-friendly, plug-and-play 75” LCD panel offering professional features such as an OPS slot, 4K UHD resolution and USB playback. This Access Series LCD panel also features 400 nits of brightness, anti-glare treatment, Miracast device connectivity, pixel shifting and a lot more. It can be mounted in either landscape or portrait orientation.
With built-in speakers, an optional touch overlay and designed for 24/7 operation, the UHD751-P can provide an interactive solution for dynamic presentations, educational collaboration or engaging retail applications. As with all Christie products, the UHD751-P is backed by Christie’s industry-leading service and support for the ultimate peace of mind.
With an optional touch overlay, the Access Series can provide an interactive solution for dynamic presentations, educational collaboration or engaging retail applications. Whether it’s an important update in the corporate boardroom or announcing the latest promotions throughout your business, you want your message to be seen and heard. With the Christie® Access Series of LCD displays, it’s easy to tell your story in a clear, impactful way.
Perfect for meeting rooms and retail applications, the Christie® UHD751-P is a budget-friendly, plug-and-play 75" LCD panel offering professional features such as an OPS slot, 4K UHD resolution and USB playback.
With built-in speakers, and designed for 24/7 operation, the UHD751-P can provide an interactive solution for dynamic presentations, educational collaboration or engaging retail applications. As with all Christie products, the UHD751-P is backed by our industry-leading service and support for the ultimate peace of mind.
Featuring the Christie FHQ842-T Interactive LCD Flat Panel Display 84". This large-format landscape 4K UHD panel delivers remarkable image quality and robust touch capability at an affordable price. Its interactive technology is well equipped with 10-point simultaneous multi-touch capability*. Allowing multiple users to interact with the screen at the same time, bringing a whole new level of group collaboration and idea sharing.
The FHQ842-T offers highly intuitive, user-friendly, interactive touch capability technology, that features precise highly responsive touch technology. It boasts such a high touch sensitivity that no pressure is required, allowing for any form of touch from a finger, gloved hand, or a pointer for example. This touch capable interactive system is compatible with Windows 7 and 8/8.1, Windows 10 Pro, Mac OSX, and Linux Operating Systems.
Using the provided USB cable, the user can connect the touch screen controller host computer to the display"s USB input. For control, this display has a 6-key control button keypad and comes with an IR remote control and an RS-232 that can be connected via an extension cable.
The FHQ842-T 84" commercial-grade LCD flat panel has UHD resolution (3840 x 2160 @120Hz) and a 1000:1 (full field) contrast ratio. With multi-window options including: Dual, Quad (allowable resolution: ≤ 1080p @ 60Hz). It also provides a wide range of inputs to easily connect any source, including an OPS slot.
Designed for use in boardrooms and meeting rooms, the Christie FHQ842-T is constructed for years of use, long runtimes, and low operating costs. This anti-glare coated panel is designed for 24/7 operation featuring a reliable power supply and cooling system. With Plug and Play (DDC2B), the ability to control on-screen display (OSD) using infrared (IR) remote control, and high-accuracy infrared touch technology this panel is very user-friendly.
*Please note that for 10-point multi-touch, the display requires Windows 7 Home Premium or higher. Mac OS or Linux requires drivers and supports single touch only.
Sl. No Description Unit Quantity. Rate Amount 1 SUB HEAD: "A": CIVIL WORK sqm 7665.85 SUB HEAD-I :- EARTH WORK Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.50 m in width as well as 10 Sq.m. on plan including disposal of excavated earth lead upto 50 m and lift upto 1.50 m. Disposed soil to be levelled and neatly dressed. a. Ordinary Soil 2 b. Hard Soil sqm 5110.56
3 Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil cum 35612.86 containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc on solidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. 4 Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and cum 28469.87 watering etc. complete.
5 Extra for every additional lift of 1.50 m or part thereof for earth work in all soils including shingles, cum 9688.14 small size boulders upto 30 cm size but excluding saturated soil and rock. (From 1.5 to 3.0 m) 6 (From 4.5 to 6.0 m) cum 9688.14 7 (From 4.5 to 6.0 m) cum 16268.88 8 Extra for every additional lift or 1.50 m or part thereof for decomposed soft or hard rock. cum 9688.14 (From 1.5 to 3.0 m)
9 (From 4.5 to 6.0 m) cum 9688.14 10 (From 4.5 to 6.0 m) cum 16268.88 11 Filling in plinth with sand under floors including watering, ramming, consolidating and dressing cum 1937.63 complete.
12 SUB HEAD-II :- CONCRETE WORKS cum 1369.04 Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. 13 Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 cum 57.97 mm nominal size) excluding the cost of centring and shuttering in : Foundations and plinth 14 Extra (over rates up to first floor level) for all concrete above first floor level. cum 1369.04 Note: 1% of the rate of concrete work from plinth to first floor level.
15 Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 sqm 314.48 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
16 SUB HEAD-III :- REINFORCED CEMENT CONCRETE WORK sqm 374.57 FORM WORK Centring and shuttering including strutting, propping etc and removal of form work for : Foundation, footings, bases of columns etc. and mass concrete. 17 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. sqm 4487.32 18 Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m sqm 12041.95 height). Note: Timber used 8 times 19 Lintels, beams, girders, bressumers and cantilevers etc. sqm 9695.29 20 Column, pillars, posts and struts etc. sqm 14917.82 21 Stairs (excluding landings) except spiral stair cases. sqm 1156.43 Note: Timber used 8 times 22 Extra for shuttering in circular work. sqm 417.45 Note: 20% of the rate of respective item of centring and shuttering. 23 metre 1540.27 Edges of slabs and breaks in floors and walls. Under 20cms wide 24 Cornices and mouldings sqm 100.00
26 STEEL REINFORCEMENT kg 2000105.85 Reinforcement of RCC work including bending, binding and placing in position complete. Tar/ TMT steel 27 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. metre 1540.27
[1/80] Page - 2 Bill of Quantities (BoQ)
Sl. No Description Unit Quantity. Rate Amount 28 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete cum 6572.09 work, using fly ash and cement content as per approved design mix, and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. NOTE- (1) Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.“ (2) Fly ash conforming to grade I of IS 3812 (Part-1) only be used as part replacement of OPC as per IS : 456. Uniform blending with cement to be ensured in accordance with clauses 5.2 and 5.2.1 of IS:456 -2000 in the items of BMC and RMC. All works upto plinth level
30 Providing and fixing of expansion joint system related with floor location as per drawings and metre 328.60 direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical locations in load application areas that accommodates multi directional seismic movement without stress to it"s components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall conform to ASTM 6063). Floor Joint of 100 mm gap 31 Providing and fixing of expansion joint system related with wall joint (internal/external) location as metre 83.60 per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063.) Wall Joint of 100 mm gap 32 Providing and fixing of expansion joint system of approved make and manufacture for various metre 82.15 roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arrangement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) Roof Joint of 100 mm gap
33 Providing & Fixing of GRC Panels Casted with Power Spray Concrete Mix Design all complete Sqm 532.62 as per architectural drawings under the direction of engineer in charge 34 Providing & Fixing of GRC Panels Casted Mouildings with Power Spray Concrete Mix Design all Meter 641.89 complete as per architectural drawings under the direction of engineer in charge 35 SUB HEAD-3A :- STONE WORK cum 141.40 Coursed rubble masonry (second sort) with hard stone in foundation & plinth with : Cement mortar 1:6 (1 cement : 6 coarse sand) 36 Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level cum 232.19 and upto floor five level. Masonry work (second sort), in cement mortar 1:6 (1 cement: 6 coarse sand) 37 Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): sqm 2321.88 Flush / Ruled/ Struck or weathered pointing
[2/80] Page - 3 Bill of Quantities (BoQ)
Sl. No Description Unit Quantity. Rate Amount 38 SUB HEAD-IV :- BRICK WORK cum 161.51 Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand). 39 Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm cum 4433.98 thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer in-Charge. (The payment of RCC band and reinforcement shall be made for separately). 40 Providing hoop iron 25 mm x 1.60 mm or equivalent reinforcement in brick masonry at every Per floor 256.47 fourth course, embedded in cement mortar. per Cum
41 SUB HEAD-V :- MARBLE & GRANITE WORK sqm 10.00 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm 42 Area of Slab over 0.50sqm sqm 507.12
43 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and metre 141.62 drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
44 Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen each 100 platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
45 SUB HEAD-VI :- WOOD AND PVC WORK cum 20.24 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class teak wood 46 Mealamine polishing on door windows by preparing the surface applying putty base course. sqm 778.37 prepare the surface smooth by sand papering and then applying mealamine polish with air compressor. Two or more coats on new works including a coat of wood filler. 47 Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and sqm 10.80 clerestory windows including aluminium butt hinges with necessary screws 38mm thick best available local wood class - B I 48 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter each 1724 bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
49 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- sqm 640.02 decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 50 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges sqm 640.02 of flush door shutters (over all area of door shutter to be measured). 51 Providing and fixing wooden moulded beading to door and window frames with iron screws, metre 1341.35 plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood 50 x 20 mm 52 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ sqm 640.02 suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick.
53 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI sqm 640.02 marked flush door shutters conforming to IS: 2202 (Part I) On one side only 54 Providing and fixing Single Glazing 6mm thick toughened glass from Gujrat Guardian Limited or sqm 1595.69 equivalent complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor ≤ 0.45, U-Value ≤ (W/sq.m-K) 5.7W /M2K, Visible light transmittance ≥ 0.30) 55 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and sqm 21.12 manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
56 Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and sqm 74.59 manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge
[3/80] Page - 4 Bill of Quantities (BoQ)
Sl. No Description Unit Quantity. Rate Amount 57 Providing and fixing fire resistant door frame of section 50 x 60mm on horizontal side & 35 x 60 Metre 478.80 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fasteners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter. The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded). 58 Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating Sqm 342.72 confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for separately). 59 Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. Sqm 342.72 beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-in-charge. The glass shall be clear, toughened, interlayered, non-wired fire resistant having 11 mm thickness of approved brand with 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 15 min of insulation (EI15) and having a sound reduction of 37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category of Impact Resistance as per EN 12600. The glass should be manufactured in UL & TUV audited Facility and including UL-EU Certification. The maximum glazing size cannot be more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report for the complete system (Glazed Door or Partition) will be considered valid only if it contains the stamp and signature of the authorized signatory from the glass manufacturer. (Actual glass size is to be measured at site for payments).
60 Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock Nos 70 on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. 61 Providing and fixing approved brand and manufacturer SS 304 grade hardware"s for Doors etc. each 530 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type fixed with SS screws etc. complete in all respects as per manufacturers" specifications & as directed by Engineer-in-charge.
62 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortice lock each 232 with key cylinder fixed with SS screws etc. complete in all respects as per manufacturers" specifications & as directed by Engineer-in-charge. 63 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long each 40 with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers" specifications & as directed by Engineer-in-charge. 64 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 150mm long each 200 with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers" specifications & as directed by Engineer-in-charge. 65 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer each 265 fixed with SS screws etc. complete in all respects as per manufacturers" specifications & as directed by Engineer-in-charge. 66 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door each 265 mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers" specifications & as directed by Engineer-in-charge. 67 Providing and fixing approved brand and manufacture SS 304 grade Top & Bottom Patch fixed each 24 with SS screws etc. complete in all respects as per manufacturers" specifications & as directed by Engineer-in-charge. 68 Providing and fixing approved brand and manufacture SS 304 grade D type 1200mm Pull Handle pair 4 with 32mm dia fixed with SS screws etc. complete in all respects as per manufacturers" specifications & as directed by Engineer-in-charge. 69 Providing and fixing approved brand and manufacture SS 304 grade D type 300mm Pull Handle pair 8 with 32mm dia fixed with SS screws etc. complete in all respects as per manufacturers" specifications & as directed by Engineer-in-charge. 70 Providing and fixing approved brand and manufacture SS 304 grade Glass to Glass Lock Round each 6 type with SS screws etc. complete in all respects as per manufacturers" specifications & as directed by Engineer-in-charge. 71 SUB HEAD-VII:- STEEL WORK Kg 51699.12 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
[4/80] Page - 5 Bill of Quantities (BoQ)
Sl. No Description Unit Quantity. Rate Amount 72 Steel work riveted or bolted in built up sections, trusses and framed work including cutting, Quintal 20.00 hoisting, fixing in position and applying a priming coat of red lead paint. In RS Joists
73 In Tees, Angles and Channels Quintal 5292.13 74 Supplying and fixing rolling shutters of approved make, made of 80 x 1.25 mm MS laths sqm 20.00 interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete but excluding the cost of the top cover and spring. 75 Providing and fixing 27.5 cm long wire spring grade No. 2 for rolling shutters. each 5
78 Providing and fixing 12 mm thick and 100 mm wide pelmet with 25 mm dia wooden curtain rod Mtr 759.43 and brackets including fixing with 25 x 3 mm MS flat 10 cm long and plugs etc complete. Timber class - A IV
79 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates kg 8268.51 etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
80 Supply and fixing of STRAIGHT PROFILED KALZIP or equivalent “SELF SUPPORTED” Sqm 6041.49 SECRET FIX STANDING ROOFING SYSTEM IN 0.9mm THICK AA 3004 ALUMINIUM ALLOY. The general roof-construction shall comprise of: Top layer – Kalzip 65-50/400-429 profiled sheet manufactured or equivalent from aluminium self supported standing seam roof system manufactured from aluminium alloy AA 3004 (AlMn1Mg1) as specified in BS EN 1396: 2007 minimum material thickness of 0.9 mm and Fluorocarbon PVDF/Stucco finish on the exposed surface. The material properties shall be as follows: Ultimate tensile strength: minimum 200 N/mm2, 0.2% Proof Stress: min 185 N/mm2, Modulus of elasticity: 70,000 N/mm2. Including Accessories, aluminium ST clips and Fasteners. Sheets are to be laid to meet the requirements of the building geometry and fixed on Aluminum clips. Clip to be fixed to the top hat/purlins with SS 304 screws only. Under Deck Insulation Liner – Kalzip 35/200 Bare or equivalent Galvalume steel liner, 0.5 mm tct, 35 mm deep ribs spanning up to 1500mm centres (multiple spans) Vapour Control layer - A single layer of double sided aluminium foil vapour barrier. Insulation - Rockwool insulation of 100mm thickness minimum 48kg/m3 density with thermal conductivity of min K=0.04 W/mk at 25 degree Celsius. Fire classification with test procedures to BS 476: Parts 6 & 7. Flashings manufactured from aluminium alloy AA 3004 (AlMn1Mg1) as specified in BS EN 1396: 2007 minimum material thickness of 0.9 mm and Fluorocarbon PVDF/Stucco finish on the exposed surface. The roofing system shall be certified with a British Board of Agreement Certificate No 98/3481 plus the Institute of Bautechnic Zulassung beschield N R -14.1 .181 All installation is to be carried out by approved trained roofing installer. The installation team shall be fully trained and approved by the manufacturer. The roof system manufacturer/supplier must have a registered office in India The approved roofing system manufacturer should have at least completed 150 projects of aluminium standing seam roofing system in India with one project having area more than 150,000 m2. Aluminium gutter of 2mm thickness with aluminium gutter expansion joints @ 12m. all complete as per direction of Engineer-in-charge. 81 Designing, providing, installing/fixing skylight consisting of 16mm thick multiwall polycarbonate Sqm 494.62 sheet in approved color (minimum 900mm wide) with standing seam on both sides & double tooth snap on locking system to ensure maximum uplift capability. The panel shall be co- extruded UV protected and antiglare/soft light to prevent glare/sun streak . The cross section of one cell should not be more than 4mmX4mm & weight of single panel shall not be less than 3250 per square metre. The system shall be fitted on purlins with spacing as specified by manufacturer with stainless steel fastener & screws and supported on MS tube framework, complete as per specification, drawing and direction of Engineer in Charge. The rate includes cost of all the operations, labour materials and tests (as applicable) for proper completion of the work except the M.S tubular framework which shall be measured and paid separately (For payment purpose the area of finished polycarbonate sheet fixed in position shall only be measured).
[5/80] Page - 6 Bill of Quantities (BoQ)
Sl. No Description Unit Quantity. Rate Amount 82 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 Metre 20.00 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron "Y" shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) 83 SUB HEAD VIII :- FLOORING sqm 579.69 Providing and laying anti skid 800x800mm Full body vitrified floor tiles (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. 84 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished sqm 1381.83 with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate. 85 Cement plaster skirting (up to 30 cm height) with cement mortar 1:3 (1 cement : 3 coarse sand) sqm 138.18 finished with a floating coat of neat cement. 18 mm thick. 86 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the sqm 5344.60 manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete Size of Tile 800x800 mm
87 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), sqm 2349.13 with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 800x800 mm 88 Providing and laying Laminate wooden flooring (Grade AC4, 8 mm thick Ambience Premium- sqm 453.51 AC4 ), having a good backing layer made up of plastic laminate or melamine as specified by the manufacturer and approved by Engineer-in-charge. Flooring 89 Skirting sqm 45.35 90 Floor strip on edges Meter 22.68 91 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as sqm 5575.86 well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 92 Extra for Shot blasted finish sqm 2230.34 93 38 mm thick wood block flooring of first class teak wood laid over 25 mm thick leveling layer of sqm 253.12 cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm nominal size) to be paid separately, coated with a thin layer of hot bitumen penetration 80/25(blown type) @ 2.45 kg per sqm, including fixing blocks in position after dipping in hot bitumen (blown type) up to half depth, planed, levelled smooth and finished complete. 94 Providing and fixing Vinyl flooring of 2mm thick PVC flexible, homogeneous antistatic calendared sqm 13.90 compacted floor covering, minimum weight 3120 g/m2 in minimum sheet of size 2mtrs. x 20 mtrs. approved pattern & colour combination with PUR Protect or equivalent surface treatment having wear minimum resistance of ≤ 4.0mm3 as per EN 660.2 and wear group P as per EN- 649 and should have a minimum residual indentation of <0.03mm confirming to EN-433. The laid flooring should have non- directional design, colour dyed as a raw mixture to ensure even colour throughout the thickness and its surface should be densely compacted for improving wear and ease of maintenance with Anti-bacterial and Fungicidal properties. The laid flooring shall confirms the fire rating B1 class as per EN 13501-1. The floor finish should terminate at the room perimeter passing over a concealed cove former and continuing up the wall for 100mm. The joints in the flooring should be sealed by using a PVC welding bar of matching colour to be supplied by the manufacturer, using a hot air gun for fusion of welding bar with flooring and self levelling required underneath with all accessories cove etc.
95 Extra for pre finished nosing to treads of steps of Granite stone. metre 1429.68 96 Extra for Granite stone flooring in treads of steps and risers using single length up to 2.00 metre . sqm 221.61
97 Providing and fixing Ist quality ceramic glazed wall tiles of size 300x450 mm conforming to IS: sqm 1401.92 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
[6/80] Page - 7 Bill of Quantities (BoQ)
Sl. No Description Unit Quantity. Rate Amount 98 Providing and fixing 18mm thick Granite stone work for wall lining at all height in cement mortar sqm 2306.91 1:3 (1cement : 3 coarse sand) including pointing with white cement mortar with an admixture of pigment to match the granite shade complete as per direction of Engineer-in-charge.
99 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in Each 13841 stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. 100 Toilet Cubical sqm 325.34 Providing and fixing Toilet Cubicle (of following standard dimension which includes 600 mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12 mm thick solid compact laminate panels Finish of the compact laminate should be raw silk which include doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawing and as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard. This also includes providing and fixing in position necessary hardware made out of Stainless Steel (Grade 316) as per manufacturer"s specifications and EIC instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicators, (4) Coat hooks, (5) U- Channels, (6) SS- Shoe Box Plate, (7) MS-Base Plate, (8) Rubber noise deafening tape, (9) Screws and wall Plugs.
101 Providing and fixing 40mm thick cladding comprising of Wooden framework using 25mx50mm sqm 1401.51 sections at a maximum spacing of 600mm in any one direction (including adding members as required) covered with12mm thick BWP ply layered with 4mm thk. veneer (Basic Rate Rs.60/- sqft)on one side pasted and pressed with adhesive to give a uniform and smooth finish, including 4mm thk. S.S. strip framework on all sides of veneer panels with wooden member surround, top moldings / margins, melamine polish etc. to finish the thickness, as shown complete in drawing. All members / ply etc. shall be treated with anti-termite solution as per norms. No extra shall be paid for making of openings, door / window frames and for making provisions for electric conduits. 102 Providing and fixing of 6mm thick lacquer glass SGG Planilaque glass of approved color by sqm 53.99 architect/ Client with SGG Planifix silicon on perfectly leveled water proof non-conventional plywood (preferably marine plywood) of minimum 12mm thickness mounted on the RCC wall/any other structure. The SGG Planilaque lacquered glass to be of 6mm thick highly durable, humid resistance, poly urethane lacquer glass. The Planilaque glass should be manufactured by industrial curtain coating process. It should meet quality standards as per BS EN 1036 1999 & confirms to PERSOZ hardness test of at least 220 oscillations. The substrate of the glass should conform to Standard BS EN 572 1995 parts 1 and 2: Glass in Building – Basic soda lime silicate glass products. Planilaque lacquered glass to be manufactured to right specifications, relating to consistency of color, opacity and homogeneity throughout production campaigns and also to the ageing properties, mechanical resistance, and resistance to humidity and to chemical agents of the lacquer. The color of the lacquer should remain stable when exposed to normal levels of ultra- violet light in interior applications.
103 Providing and fixing partition up to ceiling height consisting of GI frame work made of special sqm 1613.94 section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/ sqm(both side inclusive), consisting of floor and ceiling channel of 0.5 to 0.55 mm Metal Thickness ,72mm wide & having two flanges of 30mm each to the RCC Floor and Slab with Approved Fastener @600 mm C/C respectively. The wall studs 0.5 to 0.55 mm Metal Thickness, 70mm wide having one flange of 34mm another of 36 mm). These Wall studs are placed maximum distance of 610mm C/C in Floor and Ceiling channel. 50mm thick @ 48kg/cum density mineral wool Insulation to be suspended on Insulation Holder Strip positioned at 1200mm vertical centers within the stud cavity. One layer of 15 mm thick Firebloc Plasterboard on Both side is screw fixed to metal system using Self tapping 3.5 x 25 mm corrosion resistant drywall screws spaced at 150mm centers on all joints and 300 mm centers in the field of plasterboards. Screw fixing is done mechanically. Install Fixing Channel of 99mm x 0.90mm behind horizontal board joints and also shall be fixed 1.2m above the FFL. Finally, plasterboards and screw heads are to be jointed and finished to have a flush look which includes filling of tapered edge and square edges of board with Redi mix all purpose jointing compound, Paper Tape. (As per recommended practice of manufacturer). All perimeters and penetrations to be sealed with fire and acoustic sealant along with baker rod as per manufacturer’s specifications.
[7/80] Page - 8 Bill of Quantities (BoQ)
Sl. No Description Unit Quantity. Rate Amount 104 Providing and fixing of Noise Reduction doors (make ENVIROTECH or Equivalent ) consisting of sqm 24.36 Door frame made out of good quality hard wood , section size – 100 mm x 110 mm fitted with ‘D’ type rubber gasket to block noise leakage from gap and acoustic door shutter with minimum 60 mm thickness along with fire rating and smoke Intumescent seal strip of size 10mm x 4mm for 120 minutes fire rated and STC 37dB Tested by reputedl Laboratory and having infill of 50mm thick resin bonded glasswool of 48 kg/cum density sandwiched by two 10mm thick approved quality marine grade ply and finished with 1 mm thick laminate of approved make, shade and colour and design on both sides. Further edges of shutter shall be provided with 6mm thick teak wood beading using exterior quality synthetic adhesive, headless GI nails, screws, beading finished with approved melamine polish etc. The ply shall be resistant to vermin, mould growth, minor impact, abrasion and short term water attack and with a smooth surface suitable to receive most forms of decoration. The door shall have acoustic seal in door rebates and drop dead seal at the bottom of the door including ironmongeries. HARDWARE :-The door assembly shall be fixed to the door frame with heavy duty hardware i.e. Geze/ Assa abloy/Dorma Make or equivalent make SS Hinge Size: 4”x 3”x 3mm , 600 mm SS door handle , SS Tower bolt ,Door closer , Panic Bar ,Panic trim etc. ACOUSTIC INSULATION: The Panels filled with Acoustic material Rock wool confirming to IS-8183 of 96 kg/m3 density, very good noise absorber for high, mid & low frequencies along with, 6 MM thick anti donning layer having Thermal Conductivity 0.037 @ 20 C as per EN ISO 8497 (DIN 52613) and 2 mm thick Sound Damping layer MTS 05- 303 to achieve higher Sound STC as per site condition.
105 Providing & Fixing of Ceiling tiles shall be of high acoustic performance of Decosonic CNBM sqm 557.42 make and micro edge glass fiber in size 600x600x15 mm of color white/Black. It comprises a high-density glass wool panel covered with painted glass wool tissue for decorative ceiling effect and glass wool tissue on the backside and having sealed edges. It shall have a noise reduction co-efficient of greater than 0.90, light reflection of over 85%, density of 100kg/m3, humidity resistance. To lay the field panel of size 600x1200mm, flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre. Thus a grid system of 600mm X 1200mm is formed. Installation shall not begin until all wet work is completed and dry. Building shall be properly enclosed and under standard occupancy conditions (temperature of 20‐40°C and not more than 70% relative humidity) before installation begins. 106 P/F STRETCHED FABRIC ACOUSTIC PANELS using: sqm 629.11 • GI frame work of 48mm GI Studs, 50 mm foor using 0.55mm thick and stud channels at 610mm x 610mm, 0.5mm thick, fixed with MS angle cleats 1220x610mm centers to wall by using metal fasteners, backed with 22 SWG x 12.5mm GI Chicken Wire Mesh with air gap a minimum of 50mm on back side, as per detailed drawing. • The frame work to be filled with glass wool of 50mm thick of 48 kg/cum Cu. (Owens Corning) laminated with Black FRP Tissue on the outer side, and chicken wire mesh support on the rear side abuting the wall face. The entire glass wool surface to be covered with 12mm thick FR ply, with 8mm diameter drilled perforations at 25mm c/c in both directions. Finished in stretched fabric finish, using UPVC grippers (Waltract/ Cineview ) fixed to 50mm x 12.5mm commercial plywood runners. The fabric should be inherintly fire-retardancy. 107 STAGE FLOORING: Providing and fixing 75x25 mm teakwood plank (1500mm long) flooring Sqm 270.00 with tongue and groove joints (concealed screwing and minimum length 1.5m) on two layers of 12mm thick water proof marine ply, plywood bonded with phenolic resin with half headless GI nails/steel screws wherever necessary, with joints staggered with 2nd layer glued and screwed to the first, fixed with wooden screws to teakwood joists framework comprising 75x50mm teakwood joist 900mm centre to centre in one direction and 50x50mm teak wood battens 400mm centre to centre on other direction, teakwood joists resiliently supported on 150 x 150mm pads of 7.5mm nominal thickness of waffle, neoprene pad ribbed (50 p.s.i. grade) and 50x50x6mm thick MS angle cleat fixed with 150mm long with 10mm dia. GI bolts and expansion fasteners, over floor slab 900x900 centre to centre, support locations including providing and applying a coat of ready mixed aluminum primer and a coat of synthetic enamel paint both of approved brand and manufacturer over exposed surfaces and edges of marine ply. Entire work to be done complete as per drawings, specifications and direction of Engineer-in-Charge including wax polishing of teak wood planks after filling wood filler and sand papering up to smooth finish in natural color. Stage Floor - Moulding : Providing and fixing 145x50mm teakwood moulding as per architect on the edges of stage wooden flooring including wax polishing of teak wood planks after filling wood filler and sand papering up to smooth finish in natural color.
108 HALL FLOORING:- Providing & fixing of the cut pile designed carpet with 8mm profile underlay Sqm 1106.60 in the aisles and gangway. Complete with adhesive after rectification of the floor. Specification of Carpet: Construction - cut pile wilton weave Fiber - 2 ply twisted yarn pp Pile wt - 1100 grams / meter Pile ht - 5 to 6mm Color fastness - As per international standards
[8/80] Page - 9 Bill of Quantities (BoQ)
Sl. No Description Unit Quantity. Rate Amount 109 Providing and fixing Anutone Slats Wood based panels with lineal perforations to be fixed on Sqm 340.00 walls/ ceiling. The panels shall be fire resistant grade with melamine laminate panels 2430mm x 128mm x16mm wirh 2mm slats at 32 mm pitch, Toungue and Groove edges for seamless mounting having density of 800kg/m3 (base panel confirming to IS 12406 and laminated panel confirming to IS 14587) . The back of the panels are perforated with 10mm diameter circular holes with a nonwoven fabric covering of 0.2mm for providing Sound absorption via the acoustic impedance method. Panel is to be fixed on Anutone Strut CC18 framework with screw fixed horizontal / vertical to wall at every 600mm c/c with centre & edge bracket in tongue & groove system on CC18 framework. The cavity of framework should be inserted with polyster fibre AnutoneSynth AW 10x25 with surface density of 1000 gsm and along with all accessories and direction of Engineer in charge.
110 Providing and supplying Armstrong ‘Optra Acoustical Wall Panelling’ with square edges made of Sqm 475.00 fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and fire-resistant fabric with an option of colours as per the choice of the Architect/ Person in- charge of size 2100x600 or 1200x600 or 600x600 mm providing a minimum sound absorption level of 0.90 NRC to be affixed to wall using Wall panel impalers supplied by M/s Armstrong Industries India Pvt. Ltd and construction adhesives as per the instructions laid down by the manufacturer. Installation: Armstrong wall panel impalers of adequate quantity as specified by the manufacturer shall be fixed to the wall surface using self tapping screws. Silica based construction adhesive shall be dabbed on to the projecting elements (spikes) of the impalers.
111 Acoustic Treatment for Stage both Sides & Back wall: Providing and fixing of magnesite Sqm 350.00 bonded woodwool panels made with superfine wood fibres & gypsum, were patented with magnesite cement, edge profiles consist of Radius, Chamfer, Tongue-Groove & H-Spline groove, having density 400kg/m3, Acoustic NRC upto 0.90, eco-friendly, Fire Ratings - Non- combustibility At 750 oC, Thermal Resistance, Water Vapour Diffusion Resistant, size 600x600/1200/2400x25mm installed on Strut C-system requires unfastening and refastening of fasteners . The Strut C-System framework consisting of CC10 Channels fixed at 600mm centres, Long edges chamfer and kerfed for H-Spline; Thickness 38 mm installed on Strut C-system with H-Spline. 112 Providing and fixing of 8 mm MDF board laser cut jali with design as per drawing to be fixed over Sqm 110.00 the frame work of 48mm GI Stud/ 50mm wooden battens. The framework to be supported on the wall at a distance of 1800 mm centre to centre of size as reqd long 35x35x3mm angle cleats of required length and MS anchor fasteners of size 65mm x10mm dia. The cleats to be given two or more coats of red oxide primer. The entire work to be executed as per the drawings / instructions of the Engineer-in-charge. The rate includes for all Geometry of wall, openings etc. and for complete item including all the required approved material, labour and fixing as per drawings enclosed. The work shall be executed as per specification , & instructions of engineer in charge including cost duco paint of desired shade on the jali.
113 Providing and fixing 150 mm border out of 19 mm thick commercial block board of reputed make Rmt 200.00 like Century, Duro, Green with 1 mm laminate of reputed make like century, Greenlam as per approved shade. of approved shade. To be fixed as per the drawings over a framework of 48mm GI Stud of .55mm thk gypsteel @ 600c/c.. by means of 35x35x3MM MS angle hold fasts fixed with anchor fasteners as per drgs... 114 Providing and fixing of Anutone Subtex Nubby Soft Fibre Square edge 15mm for Ceiling of size Sqm 400.00 595x595x15 mm is to be installed on framework of Anutone Skelet. Which will comprise of NRC 0.94 base panel with humidity resistance of 90% RH and light reflectance upto 85% with Leed points Green Performance certified. Subtex Nubby Soft Fibre 15mm for Ceiling tile meet the stringent fire test required having Class ‘A’ rating for Flame Ignitability test as per ASTM-E-84, with complete framework of Anutone Skelet as per Installation details given 115 Installation Details:- Anutone Subtex Nubby Soft Fibre Square edge 15mm for Ceiling Tile is to Sqm 100.00 be layed on frame work of Anutone Skelet accessories pre-coated GI angle size 24x24x0.4 mm thick fixed to the brick wall / partition at the perimeter of ceiling with Nylon Sleeves and APS wafer head drywall screws, Then suspended main GI ‘T’ section (bottom precoated-White) with polyester coating of 25 microns dry film thickness. Main T-section size 24x38x0.3 mm thick and 3600 mm long from soffit in one direction with the help of metal rawl