USB, Ethernet and SD memory card ports deliver comprehensive connectivity, while two unique video-in and audio-out ports on all but the 5.7” model enable offer additional flexibility.
Communicate with two different PLC/devices at the same time. A serial or Ethernet port can be configured from our list of supported PLC manufacturers as a host, and the other serial port can be configured as a Sub Host communication with supported protocols including IDEC MicroSmart and Modbus RTU.
These two leading industrial communication protocols are supported in the Ethernet and Serial ports. HMI can be configured as a Client (master) or Server (slave). Setup is quick and communication to other devices is seamless.
WindO/I-NV4 software WindO/I-NV4 software is the simplest programming tool for all IDEC OI Touchscreens Series from 4.3” to 15” except the HG1F 4.6”. The WindOI-NV4 software has the same look and feel as the WindOI NV2 with all the great features, such as support of multiple protocols, FTP and Email functions. It is used to create projects that can display information from a PLC, process status, or can be used to input data with virtual switches or keypads to make changes to a process. The objects are extremely easy to configure with the help of step-by-step navigation. It lets you quickly create colorful graphical screens in no time using drop-down menus and intuitive drag and drop functionality for the objects. A workspace is available to help you organize and manage projects, objects and screens.

JSmart721 Field is the ideal product for field installation in critical areas. High-resolution 21.5” display with multitouch PCAP touchscreen with a robust glass front; touchscreen/display bonding for fidget optical performance.
Power-over-Ethernet (PoE) for maximum simplicity of connection using standard CAT5 wiring. The availability of a Wi-Fi interface enhances the device integration.

graphics controller IC for three in one operation (display, audio and touch) and its FT232R USB UART interface IC for MCU programming and communications, controlled from an inbuilt ATMEGA328P microcontroller operating at 5V/16MHz. Programming and configuration is easily achieved via the Arduino IDE, using a pre-programmed Arduino-compatible bootloader.
The development system offers a hi-quality system with an elegantly designed, precision fit bezel that provides a resistive touch panel sensor and component board in a rugged, plastic enclosure. Offered in black (-BK) colours, the device provides the engineer a low priced option which can shorten development time while enabling a production finished look for 3.5", 4.3" or 5" colour TFT display solutions.
An abundance of enhanced features are included in the "Plus" module: a backlit LED driver, inbuilt audio amplifier and micro-speaker, Real Time Clock (RTC) with battery backup, on-board 3.3v/5v level shifters, e-Flash IC build option, and a Micro-SD Card socket for application store plus 4GB SD card pre-loaded with 11 interactive application demonstrations and one library of free running apps, showcasing just a few examples of what this innovative device, designed primarily for industrial and commercial purpose, could be used for. The Arduino-compatible display system development platforms run off a standard 5V,delivered via a micro-USB or an auxiliary power connector. Furthermore, Micro-MaTch miniature connectors are provided to further extend functionality, and plug in card connectors are available to expand the IO capability to include GPIO, RS232, RS485,

On models with a HDMI video output, you can connect to a touch monitor to enable full control over the application, or to a large-screen television for displaying KPIs, trends, or other process data in your facility. Supports full HD resolution (1080p).
An alarm can be configured to not only display a message on the HMI screen in an Alarm Display, but also playback an audio alert to notify the operator of the alarm condition.
When debugging a macro, cMT Diagnoser provides line-by-line debugging and displays the values of the trace function output as well as all the declared variables.
The Combo button allows multiple actions including set bit, set word, change window, and execute macro to be performed with a single press of a button. It also displays the state of a bit or word register.
An option to use a custom bitmap that is displayed while the HMI initializes enables you to advertise your company logo or contact information every time your HMI powers up.
The Combo button allows multiple actions including set bit, set word, change window, and execute macro to be performed with a single press of a button. It also displays the state of a bit or word register.
EasyPrinter is a utility that runs on a PC that can be configured to receive data log files, event log files, recipe files, or screenshots from a Maple Systems HMI over Ethernet using the Backup object in EBPro.
EasyWatch allows users to monitor the HMI or the PLC address values via Ethernet from the PC, or to invoke the Macro for debugging, remote monitoring, and controlling. For example, In EB Pro, after creating a Numeric Input Object, you can set its address to LW-10, and set the same address in EasyWatch. The value of LW-10 will be shown in EasyWatch when successfully connecting.
Use the EasyPrinter feature to start printing to a printer connected to a PC via Ethernet. This works utilizing MS Windows so most printers on the market are supported.
File Browser object can display filenames and their directories saved in the SD card or USB disk. Apart from browsing for the files in the external devices, the filenames and the directories selected in File Browser object can be written to the designated address.
Grid Displays a grid of rows and columns in the object. The color of the grid lines can be selected. Auto fit short column (cMT Series Default style) The column width automatically adjusts to the size of the content.
Use the Label Library to create different labels or text for up to 256 different states for one language (96 states if 8 languages are used). Use the Label Library to assign text to objects on their Label tab. Multiple languages can be created for each label with the language displayed determined by system register LW-9134 (language mode).
Use a Word Lamp as a message display by assigning a Label Library to the Word Lamp. Changing the value in the register assigned to the Word Lamp will change the message displayed.
The Label Tag Library feature enables a multi-language environment. When multiple languages are required, users can create the Label Tag Library and then select a suitable label in the project. The project will display the corresponding language in runtime based on the settings. EBPro supports up to 24 different languages simultaneously.
Once the HMI is configured as a MODBUS device, the data of HMI can be read or written via MODBUS protocol. As shown in the following figure, the HMI is configured as a MODBUS device (also called MODBUS Server). The HMI, PC or other devices can use MODBUS protocol to read or write HMI data via Ethernet or RS-232 / RS-485 interface.
With Offline Simulation, you do not need to have the PC connected to the PLC. A simulated HMI screen will run on the PC that shows you how things will look on the HMI as you develop your project. All PLC values displayed in the project will revert to zero or off.
With Online Simulation, connect your PC to the PLC over either Ethernet or a serial port (a USB-to-serial converter can be used with the PC). The simulator will interact with your PLC program and display data just as if the HMI were connected to the PLC. This can save development time since you don"t have to download to the HMI every time you make a change to your project in order to test it with the PLC.
Our HMIs can be configured to operate in Serial or Ethernet Pass-Through mode. In this mode, data being sent from a PC is routed through the HMI to a PLC or controller. The Utility Manager (installed by default alongside EBPro) is used to configure Pass-Through operation.
This can eliminate the need to disconnect the PLC from the HMI when it is necessary to configure either the HMI or the PLC. Pass-through mode is only available on HMIs with an Ethernet port. An Ethernet connection from the PC to the HMI is required to initiate pass-through mode, even when using serial pass-through mode.
The PDF Reader (Smart X Series only) can display a PDF document stored on a USB flash drive or SD card. Multiple documents can be stored on the external drive and selected using the File Browser.
Use the Picture View object to display images stored on a USB flash drive or SD card. This gives you up to 32 GB worth of space enough to store and display the most complicated user manual. Supports *.bmp, *.GIF, *.jpg and *.PNG file formats. For your convenience, a scroll bar for paging through image files is built into the Picture View object.
When using Rockwell EtherNet/IP Free Tags (CompactLogix/ControlLogix) driver, the User-defined tag in RSLogix5000 can be exported to .csv file, and then imported to EBPro. However, the tags in User-Defined, Predefined and Module-Defined will not be exported. Structure Editor in EBPro is then used for importing and editing tags of data structures in User-Defined, Predefined and Module-Defined.
The selected PPD file is downloaded to the cMT model along with the project file to allow the HMI to send print jobs to a printer connected over Ethernet or USB. Status registers can be assigned to display the printer status and error codes, and command registers can be configured to update the printer status, change the printer interface (USB or Ethernet), and change the IP address and port number.
MySQL and Microsoft® SQL Server are well supported database options that can be used with our Smart (cMT) series to help collect and display data for easier monitoring and analytics. They also support a built-in database query viewer which enables production machines to retrieve data from your central SQL database.
Trend Display (Graphs) Trend Display (Graphs)
Represent complex related data in a simple format using a Trend Display. Display data in real-time with a Trend Display, plotting sampled data (Y-axis) vs. time (X-axis) in graphical format
Display data in real-time with a Circular Trend Display, plotting sampled data (radius) vs. time (circumference) in a graphical format (Advanced HMIs)
Sample Project: Real-Time Trend Display Demonstrates Real-Time Trend Display features including channel visibility, dynamic Y-axis scaling and visibility, and dynamic X-axis scaling.
Data/Event log Information: Connect with HMI via USB cable or Ethernet to check the number of history files in HMI. This feature is not supported in the Smart cMT Series.
The Media Player object is a powerful audio-visual addition, use it to play videos, show important messages, exhibit crucial warnings, and display advertising. It can also be used an analysis tool for your quality assurance program.
Now you can display information like an OEE (Overall Equipment Effectiveness) dashboard, phone lists, schedules, training manuals or inventory status. Operators now have the information they need right where they need it. Simply point the Web Browser Object to your intranet url or IP address.
You can set-up multiple windows in the HMI project that display specific web pages or web servers, and choose to show or hide the navigation bar and add additional security (passwords) to restrict user access to web pages.
network and send information to the network without requiring new Ethernet cabling, network drops, etc. This portability means that there is now added flexibility that comes with the monitoring. The HMI connects securely to the Wi-Fi network and uses it to forward requested PLC data.
Security is paramount in today"s technologically advanced times. But so is connectivity. Many PLCs take advantage of Ethernet communication to transmit data to a
monitoring device such as an HMI. Plant corporate networks, of course, can also run via Ethernet and Wi-Fi networking. But how do you get data from the PLC to your corporate network without the bandwidth or security sacrifices entailed by placing your PLC on the same network?
Maple Systems Wi-Fi HMI can connect via Ethernet or serial to your PLC on a local control network, and use its built-in Wi-Fi connectivity to send pertinent
For the industrial communications network side, an extensive library of industrial protocol drivers allow the HMI to connect to nearly any PLC on the market. Multiple protocols for different devices and different manufacturers can be used simultaneously, gathering massive amounts of data in real-time, displaying it in a digestible, intuitive way to the plant floor operator.
The XY Plot is used to plot one series of values against another series of values on a graph. This provides more flexibility than a Trend Display because one set of data can be plotted with respect to another set of data rather than just as a function of time.