5.6 color tft lcd monitor manual factory
It is advisable to change graphics adapter driver to Standard VGA Graphics adapter, accessible from Display Properties, before beginning card installation. This is because the drivers currently used by the system may not be compatible with a flat panel. Selecting Standard VGA ensures basic compatibility during the install process; thereafter the specific flat panel monitor drivers can take over for optimum performance.
T55A/T85A - (15"/18" Flat Panel Analog Monitor). This monitor has a 15-way D-type connector and plugs into a standard D-shell analog receptacle. The monitor may be used with any graphics card or port supporting SVGA or better, video output.
T55A/T85A and Matrox graphics cards - some Matrox cards support both P&D 32-way Digital connector and 15 way D-shell connectors. The 15-way monitor plug must be inserted into the 15-way socket on the Matrox card. If the PC has a graphics adapter built into the motherboard, this will be disabled when the Matrox card is installed (It is advisable to change graphics adapter driver to Standard VGA Graphics adapter, accessible from Display Properties, before beginning card installation). Connectors can be used at once without damage to monitor or PC. However the T55A/T85A must always be plugged into the 15-way socket.
T55A/T85A and T55D/T85D monitors are available shipped with Matrox G200 graphics cards. If installing with one of these cards there are two methods of installation:
Choosing "Change Driver" and selecting "Have Disk" when in Windows will load the device drivers for the card and nothing else. The Matrox display driver utilities will not be loaded. The user will have to manually set the required screen size and Color depth from display properties window.
mgasetup.exe - pre-configured display installation. Monitor configured to run at 1024 x 768 and 16 bit Color at end of installation. These are the IBM recommended settings for optimum viewing area, resolution and Color content for the T55. These drivers are not compatible with T85 monitors. The setup.exe file on the same diskette as mgasetup.exe can be used for install of a T55 monitor but without using default screen settings.
The user is advised to use the most current graphics drivers available, when using a third party graphics card. The video settings for T55 - 15" panels should be 1024 x 768 display size, 16-bit Color (65,536 Color content) and 60Hz refresh rate. For T85 - 18" panels, use 1280 x 1024 display size, 16 bit Color (65,536 Color content) and 60Hz refresh rate. If Digital flat panel support via P&D connector is available to drive a T55D/T85D, the user should follow the manufacturers instructions for installation of the graphics card and drivers.
If Windows detects a plug and play monitor, the correct INF files may be loaded from the floppy disk included in the software disk set, shipped with the graphics card. To refresh the monitor settings manually, enter from Display Properties / Settings / Advanced Properties / Monitor / Change / Have Disk and insert the INF Files diskette into drive A.
For optimum performance IBM recommend the use of 16-bit Color (65,536 Colors) for lifelike image and fast graphical manipulation. Selecting higher Color counts is at the expense of graphical throughput.
The IBM default screen size is 1024 x 768 pixels for T55 monitors and 1280 x 1024 for T85 monitors. These displays are not able to show higher resolution than their default.
T55A/T85A monitors can be configured through the monitor front panel On Screen Display (OSD) to auto-expand the display to full size. This function may also be disabled.
T55D/T85D monitors achieve higher picture stability and clarity through one-to-one digital bit mapping. Expanding the desktop is achieved by selecting the required size from Display Properties and as such there is no analog expand function accessible through the monitor.
Select 60Hz refresh rate if available. All T55/T85 monitors operate a physical refresh rate of 60Hz. If the PC supply"s frames at a higher rate, these are shadowed by the T55A/T85A monitor, which then selects the most recent frame to display at a 60Hz frequency.
Operating Instructions Thank you for purchasing this high-resolution multi-scan color monitor. Please read this guide thoroughly before installation. FCC RADIO FREQUENCY INTERFERENCE STATEMENT WARNING: (FOR FCC CERTIFIED MODELS) This monitor has been tested and found compliant with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Safety Precautions This monitor is manufactured and tested on the principle that the user’ s safety comes first. However, improper use or installation may not only damage the monitor but endanger the user as well. As a safety precaution, go over the following WARNINGS carefully before installation, and keep this guide handy.
Care and Maintenance Care Avoid exposing your monitor directly to sunlight or other heat sources. Place your monitor away from the sun to reduce glare. Put your monitor in a well-ventilated area. Do not place anything heavy on top of your monitor. Make certain that your monitor is installed in a clean and moisture-free area.
Operations: User Controls On Screen Display Control Type: Compatibility: Environmental Limits: Operating Temp Storage Temp. Operating Humidity Storage Humidity On/Off Power Button, +/- and Up/down keys Auto adjustment, Brightness, contrast color temperature, Hue, Tint, Source select, PIP setup H-position, V-position, OSD position Audio volume, bass, treble, mute Load default Digital...
DESCRIPTION : Power switch Use the power switch to turn ON or OFF power. We recommend turning your system power on first, then the LCD monitor. & + : decrement or increment the value The two keys are decrement or increment the value or enter into the sub-menu.
Color 1024x768 do the balance Color balance Intensity R Intensity G Intensity B Contrast R Contrast G Contrast B automatically. Intensity R: Adjust the R color intensity, the range is from 0 to 63 Intensity G: Adjust the G color intensity, the range is from 0 to 63 Intensity B: Adjust the B color intensity, the range is from 0 to 63 Contrast R: Adjust the R color contrast value, the range is from 0 to 63 Contrast G: Adjust the G color contrast value, the range is from 0 to 63...
The EN220 from Everfocus is a 5.6" TFT LCD CVBS test monitor & service kit. The EN220 test monitor supports CVBS analog connection. Its compact size and rechargeable battery, make this a versatile device for any installer that is looking for an efficient time saving tool for initial set up and testing.
EarthLCD is a leading “Assembled In The U.S.A.” manufacturer of Industrial ezLCD “Smart” Touch Serial LCD’s for Embedded Systems, LCD Touch Monitors, Industrial Grade LCD Kits, LCD Touch Screen Kits, Industrial NTSC Monitors & Kits, Open Frame Monitors, Smart LCD Screens, Touch Screen Monitors, Industrial LCD Touch Screen Monitors, All in one Monitors, Custom OEM solutions, Integrated Solutions for OEM, LCD Touch Screen Modules, Custom LCD Display and LCD Controller Cards.
EarthLCD is a division of Earth Computer Technologies, Inc. originally founded in 1984. A full line of products plus custom engineered solutions are available. We source LCD displays direct from major manufacturers world wide allowing for a cost advantage over our competitors. EarthLCD offer’s the world’s widest variety of LCD’s in fully integrated solutions for OEM supply chain requirements.
EarthLCD targets industries such as Point Of Sale, Industrial Automation, Security, Hospitality, Kiosks, Home Automation, OEM, Gaming, Banking, Service, Test Equipment and Monitoring, Embedded Systems, Automotive, and many other applications.